IATF16949 Practical Application | Issuing Drawings Does Not Equal Complete Design Output —— Verifiability Criteria of Ten Outputs, Input-Output Reconciliation Matrix, and Temporary Output Ledger

By: QTank Published: 11/20/2026 Views: 112
Current rating: ★★★☆☆ Rate this Equivalent to 8 ratings

A car electronics factory was undergoing a recertification audit. The auditor selected a project that had already entered mass production, opened the customer SOR, and pointed to a requirement: “-40°C cold start self-check completed within 3 seconds.” The auditor asked: Which document in the design output responds to this requirement, and how do you determine that it is met? The project engineer handed over the drawings, DFMEA, and DVP&R report, all of which matched the product, but none of them referenced the specific clause number or listed “3 seconds” as a verification value.

The auditor then asked a second question: Where are the three unresolved engineering trade-offs recorded during the DV phase? The engineer replied that they were in emails and meeting minutes.

A nonconformity was issued under 8.3.5.1. The company felt aggrieved — the drawings were issued, the DFMEA was completed, and the DVP&R involved actual testing. The auditor's logic was simple: Design outputs must be verifiable against design inputs. What you submitted are documents, not the reconciliation results.

1. The Core of the Clause is "Verifiability," Not "Having Documents"

The first sentence of 8.3.5.1 sets the criteria: Product design outputs should be expressed in a way that allows verification and validation against the requirements of product design inputs. Note that the subject is not “complete documentation,” but “expression method” — outputs must be written in a way that allows item-by-item comparison and can be determined as either passing or failing.

This can be broken down into three criteria, and if any one is missing, the output is merely an archived document:

Criterion Specific Requirement Nonconforming Example
Traceability Each output can be traced back to the specific clause number of the input, not just “customer requirements” Drawings state “designed according to customer SOR”
Measurability Outputs include numerical values, units, and criteria (≥/≤/range/sample size) “Good performance” or “meets industry standards”
Verifiability Clearly states who verifies, the method used, and the conclusion Reports only show curves, no conclusion sentences

These three criteria also determine the sequence of audit evidence collection: First, the input clause numbers, then the numerical criteria, and finally the verification conclusions. If any link is broken, the subsequent documents cannot salvage the situation.

2. The "Minimum Verifiable Form" of Each of the Ten Outputs

8.3.5.1 lists ten outputs from a) to j). The challenge is not in knowing these ten items, but in understanding to what extent each item must be delivered. The following table outlines the “minimum verifiable form” and can be used directly as a checklist (SI 30 will change the scope of i) to replacement service parts in November 2025, and this is reflected in the new criteria):

Clause Minimum Verifiable Form Audit Evidence Common Formalistic Practices
a) Design risk analysis (DFMEA) Version corresponding to project milestones; high severity items (S≥9) have individual measures, and these measures are verified in DVP&R One-to-one correspondence between high-risk measures and verification items Modify a three-year-old template and change the product name
b) Reliability study results Environmental and load profiles, sample size, confidence level, failure criteria, target values (e.g., B10 life ≥ certain hours), measured values, and margins Where the target values are written and the margins Directly attach supplier reports without comparing target values
c) Product special characteristics SC list + symbol table; consistency in drawings, DFMEA, control plan, and work instructions; symbol conversion table submitted to the customer Randomly check 3 SCs across all four documents Only mark with asterisks on drawings, no承接 in the control plan
d) Design for error-proofing results (DFSS/DFMA/FTA) List of risks such as incorrect installation, reverse installation, missing installation, polarity, and unique assembly direction, with each item assigned a “design elimination” or “manufacturing detection” conclusion Criteria for each error-proofing assignment Only state “DFMEA method applied”
e)+f) Product definition: 3D model, technical data package, 2D drawings, PMI, GD&T Consistent model and drawing versions with reconciliation; basis for datum and tolerances (tolerance stack-up calculations or process capability data); critical tolerances achievable with current processes Calculation records for tolerances, version reconciliation sheets Model V3, drawings V5, tolerances copied from old products
g) Design review results Each review records the version of the output package, issue list, responsible persons, closure status, and approvers Closure rate of issues and the flow of unresolved items Minutes state “all attendees agreed”
h) Service diagnosis and repair instructions Diagnostic procedures, fault code definitions, disassembly and assembly sequences, specialized tools, torque values, allowing after-sales to independently troubleshoot Whether after-sales actually use them Submit a generic repair manual
i) Spare parts requirements (including replacement service parts) Spare parts list, differences between spare parts and production parts, availability period Whether differences have been assessed A statement “spare parts provided separately”
j) Packaging and labeling Packaging specifications (anti-static, moisture-proof, stacking, box quantity) + label content and position + differences from customer logistics specifications Item-by-item compliance with customer logistics specifications Use old packaging specifications without re-verification

The most frequently missing items are h, i, and j. These do not participate in performance verification, and the project team often treats them as after-sales and logistics matters. However, these are precisely the items that auditors are most likely to sample and are the hardest to rectify afterward.

3. Input-Output Reconciliation Matrix: A Table to Pin Down Each Input

This matrix is the core deliverable that transforms 8.3.5.1 from a “clause” into a “daily action.” It has 12 fields, one table per project:

Field Filling Requirements
Input Number Use the same numbering system as the design input list (8.3.3.1), do not start anew
Input Source Customer SOR/Regulations/Internal targets/Lessons learned/Previous projects
Input Type Performance, regulations, interfaces, assembly, service and spare parts, packaging and labeling, cost and weight
Input Requirement Direct quotes + numerical values, no paraphrasing
Output Number Points to specific documents + clause positions (which view of the drawing, which row of the DFMEA)
Output Type One of a) to j)
Verification Method Testing/Simulation/Analysis/Review
Verification Criteria Numerical thresholds, including sample size and confidence level requirements
Responsible Person Position, not department
Evidence Location Report number or system path
Status Not covered/Partially covered/Covered/Exempted
Exemption Reason Mandatory if status is exempted, and must be signed by a customer representative

Three thresholds, to be included in the procedure document:

  1. Inputs involving SCs must be 100% covered, no exemptions allowed;
  2. Other inputs must have a coverage rate of ≥95%;
  3. Any “exemption” must have a reason and a customer representative's signature — no option for “overlooked.”

An example illustrates why this is crucial. A moderately complex project typically has 120 to 180 input requirements. One project had 148: 52 performance, 6 regulations, 24 interfaces, 26 assembly, 18 service and spare parts, 12 packaging and labeling, 10 cost and weight. The initial matrix covered 118 items, with a coverage rate of 79.7%, which doesn't seem too bad; however, the 30 missing items included 18 in service and spare parts and 12 in packaging and labeling — precisely the categories auditors love to sample and are the hardest to rectify. These gaps are invisible before the matrix is created because no one would proactively say, “I haven't reviewed the service requirements yet.”

The maintenance responsibility must be clearly defined: The matrix is maintained by the project quality engineer, updated at each phase gate, and fully reconciled with the input list when the output package is frozen. The matrix itself is not version-controlled; it will become a historical document within three months.

4. Temporary Output: The Half-Sentence in the NOTE That Is Often Overlooked

8.3.5.1 includes a NOTE: Temporary design outputs should include engineering issues being resolved through the trade-off process. This statement is often treated as a supplementary note and overlooked, but it provides a legitimate exit for “incomplete projects” — provided that these incomplete items are documented.

Engineering trade-offs happen daily: Reducing weight requires thinner material, cost reduction requires material substitution, NVH improvement requires adding dampers, and assembly requires looser tolerances. The issue is not in making trade-offs but in failing to record the decision-makers, residual risks, and data sources. Six months later, when the customer complains about unusual noises, no one can recall the original decisions.

The ledger has 10 fields:

  1. Number and date of proposal;
  2. Conflict description (Requirement A vs. Requirement B, with numerical values);
  3. Design input numbers involved (at least 1, up to 3);
  4. Alternative solutions (at least 2, including “no change”);
  5. Evaluation basis (test results, simulation, cost data, with data sources and dates);
  6. Current decision and decision-maker (position + name);
  7. Quantified residual risk (e.g., 12% performance margin, 8% life margin);
  8. Temporary measures (compensatory design, temporary testing, enhanced inspection);
  9. Affected downstream documents (DFMEA item numbers, control plan row numbers, work instruction numbers);
  10. Planned closure milestones and closure evidence.

Risk levels are categorized into three tiers, which determine whether the project can proceed:

Tier Trigger Conditions Actions
Can be closed internally Does not involve SCs, regulations, or customer interfaces; performance margin ≥20% Internal project team decision, closed before DV ends
Requires customer written confirmation Involves SCs or regulations, customer interfaces, packaging and labeling Obtain a signed deviation/concession document from the customer, verbal agreements via email do not count
Veto Safety characteristics (S≥9) without verification methods, regulations not met, SCs without verification methods Cannot proceed to the next phase, no acceptance of compensatory measures as substitutes

Three key timelines: No more than 5 items in the ledger before DV starts, and each item must have a solution; all “can be closed internally” items must be zero before PV; only items with “customer written confirmation” can be retained at PSW submission, and each must be listed in the PSW difference column. These three thresholds ensure that temporary outputs do not become permanent debts.

5. 100-Point Self-Assessment Checklist

Before freezing the output package, use this checklist to score, with a total of 100 points across six dimensions:

Dimension Points Scoring Points
Completeness 20 All ten items are present; missing items have exemption reasons and signatures; no “to be added later”
Verifiability 20 Randomly check 10 outputs, each must have numerical verification criteria; zero tolerance for adjectives
Reconciliation Coverage 20 100% for SC-related inputs, ≥95% for others; matrix and input list numbers are consistent
Special Characteristics Consistency 15 Consistency in drawings, DFMEA, control plan, and work instructions; symbol conversion table submitted
Temporary Output Management 15 All ledger fields are complete, three-tier criteria are correctly applied, timelines are met, and downstream documents are linked
Review and Release Records 10 Issue closure rate ≥95%; approver authority consistent with the authorization matrix

Three tiers of judgment: ≥85 points for release; 70 to 84 points for conditional release, with all missing items to be completed and re-evaluated within 30 days; <70 points for non-release. The score is not the key; the key is that each item must have evidence — items without evidence are directly scored as 0 points.

6. Ten Audit Evidence Questions

Ask yourself these ten questions in advance. If you can answer more than seven, 8.3.5.1 is unlikely to result in a nonconformity:

  1. Randomly select 3 input requirements; which specific output document and clause number does each correspond to? (If you cannot answer one, it is considered not covered)
  2. What is the basis for the tolerances in this GD&T, is it stack-up calculations or capability data?
  3. Are the version numbers of the 3D model and 2D drawings consistent, who reconciled them, and where is the reconciliation record?
  4. Is the SC list consistent across all four documents, and to which customer interface person was the symbol conversion table submitted?
  5. What are the sample size, confidence level, failure criteria, target values, and measured margins in the reliability study?
  6. For each item in the design error-proofing list, is it “design elimination” or “manufacturing detection,” and what are the criteria?
  7. What is the closure rate of the review issue list, and where are the unresolved items recorded?
  8. Which items in the spare parts list are replacement service parts, and who assessed the differences between them and production parts?
  9. What are the differences between the packaging and labeling specifications and the customer logistics specifications, and who confirmed these differences?
  10. How many unresolved trade-offs are there currently, who is the decision-maker, and have the residual risks been quantified?

7. Key Implementation Points and Applicability Boundaries

Do the matrix first, then the ten items. Most companies do it the other way around: they gather ten folders according to the clause and then try to explain them. The correct sequence is to first list the input requirements (8.3.3.1 already provides six categories and 32 items), then use the matrix to fill in the outputs item by item. Missing items will naturally surface — this is more reliable than making judgments based on a clause checklist.

Six Common Mistakes:

  • Treating outputs as a document list, submitting ten folders, each containing a PDF;
  • Modifying the model but not the drawings, with no version reconciliation sheet, leading to suppliers using old drawings after production starts;
  • Marking SCs only on drawings, while the control plan uses a generic template, and the symbols do not match;
  • Trade-offs exist only in the engineers' minds, and the decision basis disappears when the engineer leaves;
  • Using review minutes as a substitute for the outputs themselves — minutes state “agreed to this solution,” but the solution is not documented;
  • Treating “customer approval of PSW” as “outputs verified.” The customer approves the submission status, not your verification logic.

When to Use: Organizations responsible for product design (OEMs, Tier-1 design part suppliers) working on new platforms or major redesigns, and projects where the customer requires PPAP submission. If the design team has more than three members, it is worth building a complete matrix; for one or two people, a simplified version is sufficient — only full reconciliation for SCs and regulatory inputs, and sampling for other types.

When Not to Use: Organizations that purely manufacture according to drawings, with design responsibility lying with the customer, can trim 8.3, retaining only 8.3.5.2 for process design outputs. Applying the full ten items will only create a pile of unread documents; for minor modifications (material grade changes, appearance color changes), only applicable items need to be selected based on the impact of the change. Organizations that treat the ten items as archiving actions should not proceed — an output package that no one reconciles is more likely to expose issues during audits because it shows that you knew the requirements but did not implement them.


Outputs are not documents, but verifiable mappings of inputs.

Knowledge code: 2.1.2

Version: v20261120

Author: QTank QTank is dedicated to providing systematic professional knowledge, methodologies, and practical tools for quality management practitioners, helping companies continuously improve their quality capabilities.